Lux Level (Lighting) Testing with Test Reports(Riyadh, Jeddah & Dammam)

Too little light causes eye strain and mistakes, too much wastes energy, and emergency lighting that is too dim can leave an escape route in the dark. Star House measures lighting levels with calibrated lux meters in offices, corridors, car parks, warehouses and escape routes, compares the results with the recommended level for each space, and gives you a clear lux test report with recommendations.

Lux Level & Lighting Testing

What's included

  • Lux surveys of offices, meeting rooms, corridors, car parks and warehouses
  • Emergency and escape-route lighting tests with the normal lighting off
  • Calibrated digital lux meters, with calibration details in the report
  • Grid measurements with average, minimum and uniformity results
  • Marked-up floor plans showing every measurement point
  • Recommendations on lamps, fittings, layout and controls

When you need a lux level test

  • Handover of a new building, floor or office fit-out
  • After an LED retrofit, to prove light levels were maintained
  • Before a Civil Defense, landlord or insurer inspection of emergency lighting
  • Staff complaints about glare, dark desks or eye strain
  • Warehouse and car park safety reviews
  • Planned maintenance, to find dirty, failed or ageing fittings

How we carry out the survey

We agree the areas, standards and timing first. For normal lighting, readings are taken at desk or working-plane height on a grid across each room, with daylight excluded or recorded so it does not distort the result. For emergency lighting the normal supply is switched off and readings are taken at floor level along the centre line of escape routes, on stairs and at exit doors, fire alarm call points and firefighting equipment. Every reading is logged against a marked-up plan, and the average, minimum and uniformity are calculated for each space.

Standards we measure against

Reference values depend on the space and the code the building was designed to. Typical references are EN 12464-1 for indoor workplaces — for example around 500 lux for office desks and around 100 lux for corridors — and, for emergency lighting, NFPA 101 and the fire provisions of the Saudi Building Code: an average of about 10 lux (1 foot-candle) and a minimum of about 1 lux along the path of egress at floor level. Systems designed to European or British standards are tested against EN 1838 and BS 5266-1. Where your consultant or landlord has set a specific design level, we test against that.

Your lux test report

The report lists each area with its measured average and minimum lux, uniformity, the target value and a clear pass or attention flag, together with marked-up plans, photos and the meter's details and calibration date. Where an area falls short we explain why — failed lamps, dirty diffusers, poor fitting positions or furniture blocking the light — and recommend the most economical fix. Our electrical team can carry out the remedial work and re-test the area, so you have a complete record. Lux testing is available for offices, malls, hospitals, schools, warehouses and car parks across Riyadh, Jeddah, Dammam and the Kingdom.

Sectors we serve

Offices (core sector)MallsHospitalsWarehousesSchools

We serve clients all over Saudi Arabia — Riyadh, Jeddah, Dammam, Al Khobar, Dhahran, Jubail, Makkah, Madinah and Al-Kharj — from our head office in Riyadh (Building 2388, Al Aziziyah District).

Frequently asked questions

What lux level is recommended for an office?

For desk work such as reading, writing and computer use, the European workplace lighting standard EN 12464-1 recommends a maintained illuminance of around 500 lux on the task area, with lower levels for corridors and circulation areas. We measure against the design brief or standard that applies to your building and show any area that falls short.

Do you test emergency lighting lux levels as well?

Yes. With the normal lighting switched off we measure the emergency lighting along escape routes, stairs and exits and record whether it meets the required minimum levels. This is often combined with the full-duration emergency lighting test.

Can the test be done during working hours?

Normal lighting surveys can usually be done during the day if daylight is controlled, but the most accurate readings are taken after dark. Emergency lighting tests need the normal lighting off, so we schedule them out of hours.

Is your lux meter calibrated?

Yes. We use calibrated digital lux meters and record the instrument and calibration details in every report, so the results can be relied on in handover and inspection files.

Which areas do you cover?

We serve clients all over Saudi Arabia — Riyadh, Jeddah, Dammam, Al Khobar, Dhahran, Jubail, Makkah, Madinah and Al-Kharj — from our head office in Riyadh (Building 2388, Al Aziziyah District).

Get a free site survey

Tell us about your building — we'll inspect your systems and send a clear, single-contract proposal.